Loading...
Product Image

DVP08SN11R

★★★★ (02 Reviews)

Delta DVP08SN11R Expansion Module | 8-Channel Relay Output Unit for PLC

The DVP08SN11R from the Delta DVP-S series is the most reliable choice for driving direct electrical loads. If you have exhausted the main unit's outputs and need to control more contactors or solenoid valves, this module provides 8 additional relay outputs. These outputs offer complete isolation and the capacity to handle diverse loads, all within a slim chassis that saves valuable control panel space.

Technical Specifications of DVP08SN11R

Robust performance with safe electrical isolation:

  • Number of Points: 8 Digital Outputs.

  • Output Type: Relay.

  • Current Rating: Up to 2A per point (with a maximum total load of 5A for the module).

  • Operating Voltage: Supports both Direct Current (24VDC) and Alternating Current (250VAC).

  • Response Time: Standard mechanical response time (approx. 10ms), suitable for conventional ON/OFF applications.

  • Expansion Type: Right-side mounting for all Slim PLC units.

  • Compatibility: Fully compatible with SS2, SA2, SX2, SV2, and SE series.

Why is the DVP08SN11R the Preferred Module for Power Applications?

  • Load Flexibility: Thanks to the relay outputs, you can control devices operating at 220V AC or 24V DC directly from the module without the need for interposing relays for small loads.

  • Total Isolation: Relays provide complete mechanical and electrical isolation between the control circuits (PLC) and the power circuits, protecting the processor from voltage spikes.

  • Easy Monitoring: The module is equipped with LEDs that indicate the status of each output (ON/OFF), helping technicians visually verify the PLC's operation commands.

  • Compact and Practical Design: Provides 8 full points in a width of only 25mm, making it ideal for expanding systems without changing the electrical cabinet size.

Practical Applications of DVP08SN11R

  • Motor and Pump Control: Switching contactors for three-phase motors ON and OFF.

  • Lighting and Alarm Systems: Controlling indicator lamps, sirens, and warning lighting systems in factories.

  • Valve Circuits: Direct operation of air or water solenoid valves operating at 220V AC.

  • Simple Production Lines: Adding control points for conveyor belts or presses that rely on traditional ON/OFF logic.

The SUMER Value Proposition

At SUMER, we ensure you get the best engineering performance from your components:

  • Output Protection Support: We provide advice on using Snubber Circuits or Diodes to protect relay contact points when dealing with Inductive Loads.

  • Programmatic Addressing Coordination: We assist you in identifying the new output addresses (e.g., Y20, Y21...) to ensure seamless integration with your existing program.

  • Authenticity and Reliability: We are committed to supplying the 100% genuine Delta DVP08SN11R to ensure the long-term stability of your system.